Search for:
Home
This Month
Editorial
Contact Lenses and Silicone Allergy
more
Meeting Synopsis
ARVO Synopsis Part 2
>
more
Posters
Lactoferrin Uptake Kinetics on SiH and Conventional Hydrogel Contact Lens Materials
more
In The Practice
Hypersensitivity with Silicone Hydrogels: Material or Solution Effect? more
Tell a friend
Home
About Us
Affiliates
Contact Us
Disclaimer
Site Map

 

Quick Vote:
When refitting conventional wearers with silicone hydrogels, how frequently do you encounter possible hypersensitivity to either the materials or a material / solution combination? click

 

Would you like to subscribe to our monthly newsletter?   click
 
This site is partially funded through an unrestricted educational grant from CIBA Vision

 
Posters
April 2002

 

COMPARISON OF THE PERFORMANCE OF HIGH DK SOFT LENS PERFORMANCE ON A 6 AND 30 NIGHT EXTENDED WEAR SCHEDULES.

D Sweeney, N O'Hare, C Skotinsky, J Stern, R Wong, T Navidulah, BA Holden, CCLRU, School of Optometry and Cooperative Research Centre for Eye Research and Technology, University of New South Wales

 

Purpose:
To compare the performance of high Dk silicone hydrogel lenses worn on a six or thirty night extended wear schedule.
Method:
In a prospective 12 month clinical trial, 154 patients with previous contact lens wear history, were assigned to wear bilaterally an investigational high Dk soft contact lens on a six night or thirty night extended wear schedule. The six night group cleaned and disinfected the lenses overnight after six nights extended wear and then reinserted the lenses. Both groups disposed of the lenses after thirty nights wear. Physiological as well as lens surface performance characteristics were monitored generally using a graded scale where 0 = none and 4 = severe.

Subjective symptoms and ability to complete respective wear schedules were monitored. Patients were reviewed at one week, one month, three months and then at three monthly intervals until 12 months. The differences between the two groups were assessed by the independent student's t-test or the Mann Whitney test. The analysis of variance was used to test for trend over time.

Results:

Twelve month results for the 6 and 30 night groups are presented below.

VARIABLE
6N
30N
p-value
LR discontinuations
9% (4/45)
6%(7/116)
0.49
Limbal Hyperemia(0-4)
1.8± 0.3
1.9±0.2
0.08
Microcysts(number)
1±1
1±1
0.63
Front surface deposits(0-4)
1.2±0.6
1.1±0.5
0.41
Back surface deposits(0-4)
0.7±0.4
0.6±0.2
0.07
Wettability(0-5)
1.8±0.3
1.9±0.3
0.13
Overall comfort(1-100)
91±13
94±6
0.2
End of day comfort(1-100)
87±15
91±9
0.3
Overall vision(1-100)
88±12
93±8
0.05

% of subjects conforming to wear schedules 75 65 0.58

Conclusions:

Conclusions: With high Dk SCL EW physiological response and lens performance were excellent. In this study no significant differences (p<=0.05) were found between the 6N and 30N wear groups for the variables assessed, with the exception of overall vision.

Download PDF of Poster:
COMPARISON OF THE PERFORMANCE OF HIGH DK SOFT LENS PERFORMANCE ON A 6 AND 30 NIGHT EXTENDED WEAR SCHEDULES - PDF - 116 KB
You will need Version 4 or later of Adobe Acrobat Reader to view some documents on this site. You can get the latest version from the Adobe Home site. 

 

 
All rights reserved, copyright 2002 - 2007 siliconehydrogels.org